Extreme THC Ratios Separated the Mean From the Median in a Dried-Blood-Spot Study

The dried-spot study’s average capillary-to-venous THC ratio was strongly affected by extreme observations. Its mean and median should not be presented as interchangeable conversion factors.

The distribution was highly uneven

The reported median ratio was 2.11, while the mean was 16.6 with a very large standard deviation. Ratios ranged from 0.75 to 722. After ten observations were classified as outliers, the median became 1.84 and the mean 2.57. The remaining range still extended from 0.75 to 8.18.

Outlier removal did not establish one true correction

The authors discussed possible fingertip contamination, but did not experimentally identify the cause of every extreme observation. Statistical exclusion changes the summarized dataset; it does not prove that every excluded result was chemically false or that every retained result was unaffected.

An individual specimen needs its own context

A mean influenced by rare extremes is particularly unsuitable as a universal multiplier. Even the post-exclusion median conceals substantial variation. Preserve the sampling site, preparation, analyte and paired observations rather than converting a dried-spot THC result into a venous result with one ratio. These human specimen comparisons did not measure driving performance or validate an impairment threshold.

Related analysis: the study’s broader findings and limitations.

Research cited

Bantle and colleagues (2026). Determination of THC and THC-COOH in Dried Capillary Blood Spots and Comparison to Venous Blood of Recreational Cannabis Consumers in a Pilot Study.

Spread the love


The National Black Lawyers

top 40 lawyers

civil trial law

Lawyers of Distinction

Loading...

Recent Blog Articles

Carryover Testing Challenged the Analytical Sequence, Not the Newborn’s Exposure History

The neonatal assay’s carryover assessment examined whether a preceding high-concentration sample could affect a later measurement. It addressed an instrument-process question, not a biological exposure pathway. The protocol deliberately stressed the sequence The investigators used samples at twice the upper quantification limit followed by low-range samples. They considered contamination associated…

Spread the love

Read Article: Carryover Testing Challenged the Analytical Sequence, Not the Newborn’s Exposure History

The Paired Cord-and-Meconium Study Was Not a Survey of All Births

The forty-six specimen pairs came from archived cases in which both tests had been clinically ordered. Their cannabinoid-positive proportions were not population prevalence estimates. Selection followed the availability of paired orders Investigators sought residual meconium and cord tissue from the same newborn where testing for both matrices had been requested….

Spread the love

Read Article: The Paired Cord-and-Meconium Study Was Not a Survey of All Births

A Half-LLOQ Check Was Not the Same as Independently Determining Every Detection Limit

The neonatal cannabinoid study explicitly stated that each analyte’s detection limit was not specifically determined. It checked performance at half the lower quantification limit instead. The validation described what was actually tested The researchers verified relevant acceptance criteria and a signal-to-noise ratio of at least three at concentrations equivalent to…

Spread the love

Read Article: A Half-LLOQ Check Was Not the Same as Independently Determining Every Detection Limit

Speak with an expert today!

Contact the offices of Okorie Okorocha for professional and reliable advice which you can trust.

Call (424) 363-3347 Contact Us