Why Thirty Saliva Specimens Could Not Rank Two Cannabis Collection Devices

The thirty authentic saliva specimens in this method study were useful demonstrations of an assay, but they were not a matched comparison that could establish which collection device recovered more cannabinoid from the same people.

The two specimen groups had different exposure histories

Fifteen Quantisal specimens came from five chronic daily cannabis smokers participating in a controlled oral-THC protocol. Their histories included dronabinol dosing and smoking under that research program.

The fifteen Oral-Eze specimens came from three occasional cannabis smokers after a single smoked cannabis cigarette. Thus, collection device, participants, use frequency, route and sampling history differed together. Thirty specimens did not mean thirty independent participants.

A concentration difference has several possible explanations

If one group has higher THC or THCCOOH concentrations, the difference could reflect exposure and collection timing rather than device performance. These authentic specimens cannot isolate the device as the cause because the same participants were not sampled under matched conditions with both devices.

The separate fortified-sample validation experiments remain relevant to analytical performance in each buffer. Those experiments should be distinguished from comparisons between the two authentic-specimen groups.

The appropriate forensic use

The authentic-specimen application supports that the method could be applied to real human oral-fluid samples from those protocols. It does not establish a device conversion factor, a population detection rate or a dose–response relationship. A claimed device advantage requires a design that controls the biological and timing differences.

Related analysis: collection buffers and cannabinoid quantification.

Research cited

Concheiro, Lee, Lendoiro and Huestis (2013), Simultaneous Quantification of THC, THCCOOH, CBD and CBN in Oral Fluid by MicroFlow LC–High Resolution Mass Spectrometry. DOI: 10.1016/j.chroma.2013.04.071.

Spread the love


The National Black Lawyers

top 40 lawyers

civil trial law

Lawyers of Distinction

Loading...

Recent Blog Articles

CBN Served as the Internal Standard in a Postmortem THC Assay

The postmortem GC–MS method used cannabinol as an internal standard. CBN was a reference signal in this procedure, rather than a second reported measure of parent THC or a stable-isotope-labeled copy of it. Identify the reference compound Paknahad and colleagues described adding CBN internal standard during preparation of urine for…

Spread the love

Read Article: CBN Served as the Internal Standard in a Postmortem THC Assay

Hydrolysis Order Remained Untested in the Urinary Cannabinoid Protocol

The researchers used combined enzymatic and basic hydrolysis but did not evaluate whether reversing their order would change the result. A successful preparation procedure does not establish that alternative sequences are equivalent. Preparation defined the measured material The urinary CBD study analyzed several parent cannabinoids and metabolites by LC–MS/MS. Conjugated…

Spread the love

Read Article: Hydrolysis Order Remained Untested in the Urinary Cannabinoid Protocol

The CBD Excreted-Dose Calculation Used Volume and Molecular Weight

The study’s percentage of dose excreted was a calculated quantity using urine volume, analyte concentration and metabolite molecular-weight adjustment. It was not simply a urine concentration expressed as a percentage. The calculation had several stages For each collection, the investigators combined measured urine volume and concentration to estimate analyte amount….

Spread the love

Read Article: The CBD Excreted-Dose Calculation Used Volume and Molecular Weight

Speak with an expert today!

Contact the offices of Okorie Okorocha for professional and reliable advice which you can trust.

Call (424) 363-3347 Contact Us