Cannabis GC–MS Bias: More Signal Does Not Necessarily Mean More THC

A larger THC signal in a plant extract can reflect analytical matrix effects rather than more THC. A GC–MS study found that biases previously attributed to incomplete THCA conversion could instead arise from differences between plant extracts and neat calibration solutions.

The experiment concerned plant analysis

Researchers investigated total-THC quantitation in cannabis extracts, including chromatographic separation, injection conditions, isotope-labeled standards and analyte protectants. The specimens were plant extracts and laboratory solutions, not human blood or urine.

Here THCA means tetrahydrocannabinolic acid, the plant precursor that can decarboxylate to THC. That name must not be confused with papers using “THCA” for the carboxy metabolite of THC.

Conversion and surface activity were separate mechanisms

Under the tested extract conditions, THCA converted efficiently to THC, including at relatively low injection temperatures. The authors concluded that decarboxylation was not the source of the observed bias in those experiments.

Instead, plant matrix increased analyte response compared with neat solutions. Surface adsorption, including effects associated with active silanol sites, contributed to response differences. External calibration was particularly vulnerable to such mismatch.

Why internal standards and protectants helped

Isotope-labeled compounds allowed the researchers to distinguish relevant species and study the analytical process. Analyte protectants reduced problematic adsorption and improved consistency between preparations.

This does not mean that every gas-chromatography method automatically achieves complete conversion or that every matrix effect disappears after adding one standard. The result belongs to the tested instrument conditions, materials and workflow.

Implications for a potency dispute

Review whether standards and samples behave comparably, whether the method separates relevant cannabinoids, and how conversion and adsorption were independently assessed. A strong calibration line in neat solvent cannot alone establish unbiased results in plant material.

The study offers a concrete explanation for some potency-measurement discrepancies. It does not establish the absorbed dose from consuming a product or permit conversion of plant total THC into a person’s blood concentration or impairment level.

For context, see our discussion of THC concentrations and the separate question of impairment.

Primary research

Jerome Mulloor and colleagues. New perspectives on THCA decarboxylation and accurate GC–MS quantitation of Total THC in Cannabis using analyte protectants. Forensic chemistry (Amsterdam, Netherlands) (2025). DOI: 10.1016/j.forc.2025.100668.

Spread the love


The National Black Lawyers

top 40 lawyers

civil trial law

Lawyers of Distinction

Loading...

Recent Blog Articles

Other Medications Changed THC/CBD Spray Exposure in Different Directions

The effect of another medication on THC/CBD exposure depends on the drug and the pathway involved. A human interaction study found lower cannabinoid exposure with rifampicin, higher exposure with ketoconazole, and no significant pharmacokinetic change with omeprazole under the tested conditions. Three separate crossover comparisons Stott and colleagues studied 36…

Spread the love

Read Article: Other Medications Changed THC/CBD Spray Exposure in Different Directions

An Intermediate CBD Stress Response Was Not a Significant Placebo Difference

A CBD group’s average response can fall between placebo patients and healthy controls without demonstrating a significant CBD-versus-placebo benefit. A study of social stress in people at clinical high risk of psychosis illustrates this statistical distinction. Stress hormones and subjective symptoms were separate endpoints Participants at clinical high risk received…

Spread the love

Read Article: An Intermediate CBD Stress Response Was Not a Significant Placebo Difference

Two-Dimensional Cannabis GC–MS Testing Needs Correctly Timed Transfer Windows

Adding a second chromatography column can improve cannabinoid separation while introducing a new failure point: the analyte must reach the second column during the correct transfer window. A plasma assay study showed why those windows require verification. More separation brought more timing requirements Karschner and colleagues developed two-dimensional gas chromatography–mass…

Spread the love

Read Article: Two-Dimensional Cannabis GC–MS Testing Needs Correctly Timed Transfer Windows

Speak with an expert today!

Contact the offices of Okorie Okorocha for professional and reliable advice which you can trust.

Call (424) 363-3347 Contact Us