A 0.63 Blood-to-Plasma Ratio Was an Assumption in the Inhaled-THC Model

The inhaled-THC modeling study used a blood-to-plasma ratio of 0.63 to relate whole-blood measurements to plasma-based pharmacokinetic work. It did not measure that ratio separately in every participant.

The original specimens were whole blood

Researchers quantified THC in whole blood. For model comparison and fitting, they applied an external ratio to connect those values with the plasma framework used in earlier studies. The transformed concentration therefore depended on both a laboratory measurement and a matrix assumption.

Conversion does not create a paired plasma specimen

A calculated plasma-equivalent value should not be labeled directly assayed plasma THC. The ratio’s use in one modeling exercise also does not establish that it is constant across all individuals, collection intervals or analytical settings. The current data did not independently test every such application.

Keep the matrix in the scientific conclusion

The model’s estimated doses and parameters should be interpreted with that conversion in view. Quoting a numerical concentration without specifying whether it was measured or transformed loses information relevant to uncertainty. Neither a whole-blood result nor its calculated plasma counterpart supplies a functional impairment finding. For a disputed comparison, identify the original specimen and the conversion basis before treating two reported numbers as directly comparable observations.

Related analysis: the study’s broader findings and limitations.

Research cited

Henthorn and colleagues (2024). Dose Estimation Utility in a Population Pharmacokinetic Analysis of Inhaled Δ9-Tetrahydrocannabinol Cannabis Market Products in Occasional and Daily Users.

Spread the love


The National Black Lawyers

top 40 lawyers

civil trial law

Lawyers of Distinction

Loading...

Recent Blog Articles

CBN Served as the Internal Standard in a Postmortem THC Assay

The postmortem GC–MS method used cannabinol as an internal standard. CBN was a reference signal in this procedure, rather than a second reported measure of parent THC or a stable-isotope-labeled copy of it. Identify the reference compound Paknahad and colleagues described adding CBN internal standard during preparation of urine for…

Spread the love

Read Article: CBN Served as the Internal Standard in a Postmortem THC Assay

Hydrolysis Order Remained Untested in the Urinary Cannabinoid Protocol

The researchers used combined enzymatic and basic hydrolysis but did not evaluate whether reversing their order would change the result. A successful preparation procedure does not establish that alternative sequences are equivalent. Preparation defined the measured material The urinary CBD study analyzed several parent cannabinoids and metabolites by LC–MS/MS. Conjugated…

Spread the love

Read Article: Hydrolysis Order Remained Untested in the Urinary Cannabinoid Protocol

The CBD Excreted-Dose Calculation Used Volume and Molecular Weight

The study’s percentage of dose excreted was a calculated quantity using urine volume, analyte concentration and metabolite molecular-weight adjustment. It was not simply a urine concentration expressed as a percentage. The calculation had several stages For each collection, the investigators combined measured urine volume and concentration to estimate analyte amount….

Spread the love

Read Article: The CBD Excreted-Dose Calculation Used Volume and Molecular Weight

Speak with an expert today!

Contact the offices of Okorie Okorocha for professional and reliable advice which you can trust.

Call (424) 363-3347 Contact Us