Six HHC Cases Showed Different Concentrations in Blood and Plasma

HHC concentrations differed substantially between whole blood and plasma in a small casework series. The observed blood-to-plasma ratio came from six HHC-positive cases; it should not be turned into a universal conversion factor or an impairment threshold.

An analytical method with a small HHC application

The researchers validated an LC–MS/MS assay measuring THC, two THC metabolites, CBD and HHC. It was applied in routine forensic casework, including six cases in which both blood and plasma were available for HHC analysis.

HHC plasma concentrations ranged from 2.1 to 37.0 micrograms per liter, while blood concentrations ranged from 0.6 to 9.1 micrograms per liter. The reported blood-to-plasma ratio was approximately 0.28, with individual ratios from 0.24 to 0.39.

Two kinds of matrix comparison must be separated

The laboratory demonstrated that plasma-based calibration could quantify analytes added to whole blood within its validation criteria. That is an analytical calibration finding.

It does not mean that authentic whole blood and separated plasma contain identical concentrations after exposure. In the HHC cases, the paired specimens showed that these physiological matrices could yield different numerical values even when analyzed with the same validated workflow.

The HHC result combined two forms

The method did not chromatographically separate the 9R and 9S HHC diastereomers; it reported their combined HHC concentration. It also did not measure HHC metabolites.

An isotope-labeled HHC internal standard was unavailable during development, so the assay used labeled THC for HHC quantitation. The authors identified a matched HHC internal standard and expanded metabolite coverage as improvements. These limitations should accompany comparisons with methods that measure different HHC targets.

What six observations cannot resolve

Consumption histories and the timing between the vehicle-related event and blood collection were not available. The HHC case series did not establish a concentration–performance relationship or a validated model for back-calculating event-time concentrations.

The paper’s main experimental contribution is analytical measurement. Its general discussion of impairment does not substitute for a controlled HHC driving study. A case review should retain the actual specimen matrix and assay definition before considering any broader interpretation.

Related: Interpreting THC concentration and impairment.

Primary research

Quantification of ∆9-tetrahydrocannabinol, 11-OH-THC, THC-COOH, hexahydrocannabinol, and cannabidiol in human plasma and blood by liquid chromatography–tandem mass spectrometry. DOI: 10.1093/jat/bkae094.

Spread the love


The National Black Lawyers

top 40 lawyers

civil trial law

Lawyers of Distinction

Loading...

Recent Blog Articles

CBD Epilepsy Trial Liver-Enzyme Events Often Involved Concomitant Valproate

Liver-enzyme events during CBD epilepsy trials often occurred in patients also taking valproate. That pattern makes the full medication regimen important, but it does not isolate which drug caused an individual event or establish safety without valproate. The finding came from treated epilepsy populations An original reanalysis of four randomized…

Spread the love

Read Article: CBD Epilepsy Trial Liver-Enzyme Events Often Involved Concomitant Valproate

Serum Cannabinoid Fingerprints Did Not Reliably Separate Medical and Street Cannabis

A broad serum cannabinoid panel did not reliably distinguish THC-rich medical cannabis from street cannabis in a pilot study. More analytes supplied useful patterns, but they did not create a universal test for prescription-source attribution. Different products were represented The study recruited 23 patients receiving cannabis-based medicines or medical cannabis…

Spread the love

Read Article: Serum Cannabinoid Fingerprints Did Not Reliably Separate Medical and Street Cannabis

Stored Cannabinoid Urine Screens Lost Signal Without Measuring Chemical Degradation

A stored urine specimen can lose cannabinoid screening response, but the response alone does not reveal exactly how much of a named compound chemically degraded. An analog-stability study used immunoassay signal as its endpoint rather than compound-specific mass-spectrometric concentrations. The experiment used fortified human urine Researchers added individual cannabinoid analogs…

Spread the love

Read Article: Stored Cannabinoid Urine Screens Lost Signal Without Measuring Chemical Degradation